Recirculation of the water on Module 1 takes the water from the sump of the module and pumps it down the load chute of the CBW. This water serves to push the goods down the load chute, thus requiring less flush water, which reduces the water consumption of the machine. RECIRCONE can be added to an existing Milnor CBW. It was standard on all PulseFlow machines.

Another benefit to Recirc is the chemistry in the water in module 1 is sprayed down through the goods and there is tremendous wetout and chemical penetration into the structure of the fabric. The faster chemicals make contact with the fabric, it will accelerate the washing process.

Attached are some marked up schematics showing the wiring that would have to take place to install RECIRC to an existing CBW.

RECIRC
RECIRCONE
RECIRC ONE
Mod 1 Recirc
Mod one Recirc
ModOneRecirc
These are the part numbers to install Recirc to an existing CBW.

KTDARRHV01 - RECIRC RETRO HIGH VOLT 380V-480V

KTDARRLV02 -RECIRC RETRO LOW VOLT 200V-240V

CSH 08/23/12