Pellerin Milnor Corporation

Technical Knowledge Base

Dryer Sprinkler

Dryer Sprinkler Trip Assembly
Maintenance Bulletin: B22MB93002
Release Date: August 13, 1993

Subject: Dryer Sprinkler Trip Assembly
DISTRIBUTION MAINTENANCE BULLETIN B22MB93002
01234567-5-1XXXXXXXXXX
August 13, 1993


SUBJECT: DRYER SPRINKLER TRIP ASSEMBLY

SAFETY BULLETIN

Dear MILNOR Dealer/Customer:

In the recent past, we have learned that there is a possibility the linkage pivot latch on the solenoid in the dryer sprinkler trip assembly can bind in the exit hole of the solenoid box. If the linkage pivot latch binds, it could prevent the sprinkler system from extinguishing a fire. When actuation the sprinkler trip assembly, the linkage pivot latch can bid in either direction in the exit hole.

Enclosed is a set of instructions for enlarging the exit hole in the solenoid box. This should prevent the assembly form binding.

Yours truly,

PELLERIN MILNOR CORPORATION

Daniel H. Albers
Last updated: 11/17/2006 / Node ID: 638 / Key Chain: 12.1.13.36.27E.